LED Driver Constant Voltage Waterproof Switching Power Supply
Product descriptions
Features: | |||||
Constant voltage style power supply | |||||
universal AC input range | |||||
Small volume,low weight,high efficiency | |||||
Protections: short circuit/over load/over voltage/over temp | |||||
Cooling by free air convection | |||||
Fully encapsulated with IP67 level | |||||
100% full load burn-in test | |||||
2 Years warranty | |||||
output | DC voltage | 12V | 24V | 36V | 48V |
Voltage tolerance | ±1% | ±1% | ±1% | ±1% | |
Rated current | 8.5A | 4.2A | 2.8A | 2.1A | |
Current range | 0~8.5A | 0~4.2A | 0~2.8A | 0~2.1A | |
Rated power | 102W | 100.8W | 100.8W | 100.8W | |
Ripple&noise | 100mvp-p | 150mvp-p | 150mvp-p | 180mvp-p | |
input | Voltage range | 90~264VAC,126~373VDC | |||
Frequency | 47~63HZ | ||||
AC current | 2.4A/115VAC,1.2A/230VAC | ||||
Efficiency | 82% | 84% | 84% | 85% | |
Inrush current | Cold start current20A/115VAC,40A/230VAC | ||||
Leakage current | <2.5mA/240VAC | ||||
protection | Over load | Rated output power105%~135%start over load protection | |||
Protection type: hiccup mode,auto-recovery after fault condition is removed | |||||
Over voltage | 15.6~17.8V | 30.6~33.2V | 42.6~44.2V | 54.8~56.6V | |
Protection type: hiccup mode,auto-recovery after fault condition is removed | |||||
Over temperature | Shell temp≥85℃,start over temperature protection | ||||
Protection mode: cutoff output,auto-recovery after temperature become normal | |||||
environment | Working temp,humidity | -10℃~+60℃,20%~90%RH | |||
Storage temp.humidity | -20℃~+85℃,10%~95%RH non condensing | ||||
Withstand vibration | 10~500HZ,2G10min/1cycle,period for 60minutes,each axes | ||||
safety | Withstand voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||
Fits | Safety standard | Fit UL1012,IP67 protect level | |||
standard | EMC standard | Fit EN55022,CLASSA | |||
Others | Dimension | 185*69*43mm(L*W*H) | |||
Weight/packing | 0.9kg/20pcs/19kg/0.026 m³/0.91CUFT | ||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. | ||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||